Figure 33: Connection of a safety locking device to the EMSS node
1
EMSS node
2
Connecting cable M12, 8-pin, male/female connector
3
Safety locking device i10 Lock, i10-M0454
Pin assignment
8-pin EMSS (female connector)
Signal
Pin assignment
i10 lock, i10-M0454
(male connector)
1
VDC
1
2
AUX_IN
2
3
EMSS1_A
3
4
EMSS1_B
4
5
AUX_OUT
5
6
GND
6
7
EMSS2_A
7
8
EMSS2_B
8
Table 11: Pin assignment safety locking device to EMSS node
Implementation with the Flexi Soft safety controller
The lock must be implemented in the Flexi Soft Designer logic editor (see the “Flexi
Loop in the Flexi Soft Designer” operating instructions, part no. 8014522).
Figure 34: Lock with the Flexi Soft safety controller
1
Safe cut-off path (guard position monitoring of the protective device and the interlocking
device)
DESIGN
4
8015836/YT10/2016-05-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
37