10.1.7
MSTR Flexi Loop accessory
FLA-MSTR00001
FLA-MSTR00002
Test inputs for the Flexi Classic connection layout (FC_A1 and FC_B1)
Input voltage HIGH
13 … 30 V DC
Input voltage LOW
–5 … +5 V DC
Input current HIGH
3.5 … 6.2 mA
Input current LOW
–2.5 … +2.5 mA
Test outputs for the Flexi Classic connection layout (FC_A2 and FC_B2)
Maximum short-circuit currents
13.5 mA
Table 55: Data sheet MSTR Flexi Loop accessory
Additional data on the variant FLA-MSTR00002 with IO-Link interface
FLA-MSTR00002
General electrical data
Supply voltage (V
S
) on usage of IO-
Link
18 … 30 V DC
Non-safe output (C/Q or AUX_OUT)
Type of output
Highside driver, short-circuit protected, or IO-Link
Output current
Max. 50 mA
Permissible capacitive load
Max. 100 nF
Debouncing
100 ms
Non-safe input (AUX_IN)
Logic level switching points
HIGH
>13 V/3.5 mA
LOW
<5 V/2.5 mA
Maximum input current
6.2 mA
Debouncing
100 ms
Table 56: Additional data on the FLA-MSTR00002 variant
10
TECHNICAL DATA
86
O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
8015836/YT10/2016-05-24 | SICK
Subject to change without notice