The safe sensor cascade is connected to one output (X) and two safe inputs
(I) of an
I/O module.
The safe sensor cascade can be connected to the same voltage supply as the safety
controller. However, the current must be limited to 4 A.
Figure 41: Connection to Flexi Soft
Use 5-pin cables with M12 female connector and open cable ends to connect the safe
sensor cascade (
see "Pre-assembled cables", page 95
6.2.2
Connection to Flexi Classic
Figure 42: Terminals on the Flexi Classic main module
1
Terminals for inputs and outputs
The figure shows the terminals for inputs and outputs based on the example of the
UE410-MU main module. The terminal pin assignments are listed in the “Flexi Classic
Modular Safety Controller” operating instructions.
ELECTRICAL INSTALLATION
6
8015836/YT10/2016-05-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
43