FLA-MSTR00002
Figure 17: FLA-MSTR00002 Flexi Loop accessory
The MSTR2 Flexi Loop accessory connects a safe sensor cascade to a Flexi Classic
safety controller. It requires two test signal outputs (X) and two safe inputs (I) on a Flexi
Classic module. In addition the MSTR2 Flexi Loop accessory is used to monitor the sys‐
tem during commissioning and in operation.
The MSTR2 Flexi Loop accessory
also has a non-safe input and a non-safe output. The
non-safe output is used alternatively as an IO-Link interface.
The non-safe input of the Flexi Loop MSTR2 accessory is used to control actuators at
the non-safe outputs of the Flexi Loop nodes.
The non-safe output of the Flexi Loop MSTR2 accessory is used to transmit switching
signals at the non-safe inputs of the Flexi Loop nodes to a standard controller.
The MSTR2 Flexi Loop accessory exchanges process data and service data with a PLC
via the IO-Link interface.
FLA-DIAG00001
Figure 18: FLA-DIAG00001 Flexi Loop accessory
The Flexi Loop DIAG accessory is used for the following purposes:
•
Status indicator in the safe sensor cascade during operation
•
System monitoring during a wiring test without a safety controller configured
PRODUCT DESCRIPTION
3
8015836/YT10/2016-05-24 | SICK
O P E R A T I N G I N S T R U C T I O N S | Flexi Loop
23