EN – 8
Perform the Drain Water function at least once a day
after cooking with steam. It takes up to 7 minutes.
Drain Water function is ver y useful to prevent
scale build up and the use of stale water. It causes
evaporation of the internal steam system.
P R O C E D U R E
1
Press
Start/Instant Cook
.
“In F1” will fl ash on and off in
the display during the Drain
Water function.
2
Remove the water tank. Ensure
that no food is in the oven.
Press
Info/Timer
once to select
“In F1”.
When the drain function has ended and the
oven is cool, wipe oven cavity.
Empty the drip tray.
3
NOTES:
1. The water tank must be removed before starting
this procedure.
2. If Drain Water Function is set, Energy Save Mode
will be cancelled temporary.
W h i t e o r g r ay g r a i n s , a l s o c a l l e d s c a l e , m ay
for m in the water circuit inside the oven during
steam generation, which could cause the oven to
malfunction.
When "DESCALE (fl ashing)" is shown in the display,
be sure to carry out Descale function immediately. It
takes about 1 hour. (The descaling using citric acid or
lemon juice is for about 30 minutes, and then rinsing
with fresh water is for about 30 minutes.)
P R O C E D U R E
1
3
Do not place any food in the
oven. Close the door fi rmly.
Press
Start/Instant Cook
to
begin descaling. (about 30 min.)
4
When the oven has stopped and is cool, remove
water tank, empty, rinse and refi ll with room
temperature water suitable for drinking (fi ltered)
to the MAX mark. Replace the water tank.
Empty the drip tray and replace it.
Remove glass tray, empty, rinse
and dry. Follow step 3 to replace
glass tray. Close the door fi rmly.
Press
Start/Instant Cook
.
Rinsing will start. (about 30 min.)
5
When rinsing has ended and the oven is cool,
remove water tank and empty. Remove glass
tray and empty. Wipe oven cavity to dry. Empty
the drip tray.
6
Place the glass tray in lower position (position 2)
closely to attach to the back side of the oven
wall.
NOTE:
If Descale Function is set, Energy Save Mode will be
cancelled temporary.
IMPORTANT INSTRUCTIONS
Descale Function
Drain Water Function
x 1
x 1
Press
Info/Timer
twice to
select “In F2”.
x 2
2
x 1
x 1
Pure citric acid, available at some drugstores,
or bottled 100% lemon juice with no pulp are
used for descaling. Choose one and prepare
the descaling solution.
To use pure citric acid, dissolve 1 tablespoon
of pure citric acid crystals in 500ml of water in
a non-porous container. Stir well and pour into
the water tank to the MAX mark.
To use 100% bottled lemon juice, check that
there is absolutely no pulp in it. If there is
pulp or you are not sure, strain through a fi ne
strainer. Measure 70ml of the strained lemon
juice and add it to 500ml of water. Stir well and
pour into the water tank to the MAX mark.
Place the water tank in the oven correctly and
push fi rmly into place.
SRH AX1100R̲en.indd 8