Purpose
Setting
Function
(Purpose)
Used to set the CE mark conforming operation mode.
(For flickers when driving the fusing heater lamp.)
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
Enter the number corresponding to the operation mode
with the 10-key and press the [OK] key.
Set value
Content
0
CE mark control inhibit
1
CE mark control allowed
0: Normal operation heater lamp slow up control
1: CE mark standard complying operation (Heater lamp slow up con-
trol) (Europe)
26 - 32
Purpose
Setting
Function
(Purpose)
When the variable speed fan motor is in the ready state
and the process temperature is in the range of 36° –
45°, the PWM duty is set in percentage.
(AR-287/337/407/507)
Item
Operation
Operation/
Procedure
When this simulation is executed, the current set value
is displayed. At that time, select the fan motor with [
]
key and [
¯
] key. Then the set value can be changed
with the 10-key.
When [
] key or [
¯
] key is pressed, the current set value is stored in
the EEPROM.
VFM1&2&4
Adjustment range of 50 – 100% in 1% increment
PCFM VFM5&6 Adjustment range of 50 – 100% in 1% increment
26 - 35
Purpose
Setting
Function
(Purpose)
Used to set whether the trouble history display of SIM
22-4 is displayed as one trouble or as the number of
continuous troubles when two or more troubles of a
same kind occured.
Item
Specifications
Operation/
Procedure
Used to set whether the trouble history display by SIM
22-4 is displayed as one trouble or as the accumulated
number of continuous troubles when two or more trou-
bles of same kind occur continuously.
Select the number corresponding to the display mode with the 10-key
and press the [OK] key.
1: The trouble history display by SIM 22-4 is displayed as it is when
two or more troubles occur continuously.
0: The trouble history display by SIM 22-4 is displayed as one trouble
when two or more troubles occur continuously.
Default: 0
26 - 36
Purpose
Setting
Function
(Purpose)
Used to set the ICU fan operating temperature. (Opera-
tion in pre-heat mode.) (Excluding Japan models.)
Section
ICU
Item
Operation
Operation/
Procedure
Used to set the threshold value of the ambient tem-
perature for turning ON the ICU fan motor in the pre-
heat mode.
Set range : 0~33[°C]
Default : 30[°C] (30)
Enter the operating temperature with the 10-key pad
and press the [OK] key.