65
65 - 1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the touch panel (LCD display) detecting
position.
Section
Operation (Display/Operation key)
Operation/
Procedure
Touch the four cross marks.
The coordinates at the pressed point are set.
When the coordinates are properly set, the display turns to gray and
returns to the simulation sub code entry screen.
In case of an abnormality, it returns to the input display.
65 - 2
Purpose
Operation data output/Check (Display/Print)
Function
(Purpose)
Used to check the result of the touch panel (LCD dis-
play) detecting position adjustment. (The coordinates
are displayed.)
Section
Operation (Display/Operation key)
Operation/
Procedure
When the touch panel is pressed, the AD value in each
of X and Y directions at that point and the coordinate
values are displayed in ( ) as well as the coordinate val-
ues of each point.
It is based on the coordinates set with SIM 65-1.
67
67 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the printer PWB memory operation
(read/write). (When replacing the PWB with a new one,
this check must be performed.)
Section
Printer
Item
Data
Operation/
Procedure
1. When SIM 67-1 menu is displayed, the operation
check of all memory (DRAM, SIMM1, SIMM2) of the
printer section is started.
2. For the RAM the operation check of which is started, "--------" dis-
play is changed to "CHECKING." When checking is completed,
the check result is displayed with "OK" or "NG."
When SIMM is inserted, the memory capacity is also displayed as
"OK(16MB)."
67 - 2
Purpose
Operation test/check
Function
(Purpose)
Used to check the printer parallel I/F operation. (This
simulation is used only for production, and a special
tool is required. Not available in the market.)
Section
Printer
Item
Operation
Interface/Communication
Operation/
Procedure
7/13/2000
7 – 55
Содержание AR-250
Страница 194: ......