14
14 - 0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self diag U1/LOC/U2/PF troubles.
Item
Trouble
Error
Operation/
Procedure
When the [EXECUTE] key is pressed, the troubles ex-
cluding U1/LCC/U2/PF are canceled and the display re-
turns to the simulation main code entry screen.
After this simulation is canceled, the machine resumes operation.
15
15 - 0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self diag U4 - 09/20/21/22 (large ca-
pacity tray) trouble.
Section
Paper transport
Item
Trouble
Operation/
Procedure
When the [EXECUTE] key is pressed, the U6
(09/20/21/22) (LCC) trouble is canceled and the display
returns to the simulation main code entry screen.
After canceling this simulation, the machine resumes
operation.
16
16 - 0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel the self diag U2 trouble.
Item
Trouble
Error
Operation/
Procedure
When the [EXECUTE] key is pressed, the U2 trouble is
canceled and the display returns to the simulation main
code entry screen.
After this simulation is canceled, the machine resumes
operation.
17
17 - 0
Purpose
Clear/Cancel (Trouble etc.)
Function
(Purpose)
Used to cancel copy inhibition by the host computer
during the self diag PF.
Section
Communication unit (TEL/LIU/MODEM etc.)
Item
Trouble
Error
Operation/
Procedure
When the [EXECUTE] key is pressed, the PF trouble is
canceled and the display returns to the simulation main
code entry screen. After this simulation is canceled, the
machine resumes operation.
21
21 - 1
Purpose
Setting
Function
(Purpose)
Used to set the maintenance cycle.
Item
Specifications
Counter
Operation/
Procedure
When the maintenance cycle is selected with the key,
the selected key is highlighted. The maintenance mes-
sage is displayed in every selected cycle. When FREE
is selected, the maintenance display is not shown.
(AR-250/280/281/285/286/287/335/336/337)
Default: 80K
7/13/2000