26 - 3
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the auditor. Setting
must be made depending on the use condition of the
auditor.
Section
Auditor
Item
Specifications
Operation/
Procedure
Enter the code number corresponding to the auditor
specification mode with the 10-key pad and press the
[OK] key.
Set value
Specification mode
1
Built-in auditor mode (Default)
2
Coin vendor
3
Others
26 - 5
Purpose
Setting
Function
(Purpose)
Used to set the count mode of the total counter and the
maintenance counter.
Item
Specifications
Counter
Operation/
Procedure
Used to set the single count-up or double count-up for
the total counter, the maintenance counter, and the de-
veloper counter when printing is performed with A3, 11
x 17" paper,
1. Select the kind of the counter with [
] and [
¯
] key.
A
Total
B
Maintenance
C
Developer
2. Enter "1" or "2" with the 10-key pad and press the [OK] key.
1: Single count
2: Double count
Default: 2
26 - 6
Purpose
Setting
Function
(Purpose)
Used to set the specifications depending on the desti-
nation.
Item
Specifications the
destination
Destination
Operation/
Procedure
Select the destination referring to the table below.
U.S.A.
United States of America
Canada
Canada
Inch
Inch series, other destinations
Japan
Japan
AB_B
AB series (B5 detection) other destinations
Europe
Europe
U.K.
United Kingdom
Aus.
Austrailia
AB_A
AB series (A5 detection) other destinations
When the destination setting is changed, the following specification is
changed.
(Toner save mode setup specification) (Paper specification)
26 - 10
Purpose
Setting
Function
(Purpose)
Used to allow entry of the software key input for the
network scanner. (AR-287/337/407/507)
Item
Operation
Operation/
Procedure
1. After entering the sub code of the simulation, enter
the software key in the obtained frame of "NEW."
2. When the obtained number is entered with the 10-key (max. 9 dig-
its), the entered number is displayed in the frame of "NEW." After
entering the number, press the [OK] key, and the entered number
is stored.
3. Reset with the CA key, and the scanner function is enabled.
*
Only when SCSI (20 channels/NS1) setup is completed.
If the scanner key input is made without setup, it is rejected.
4. Special note
When the SCSI channel is set to "20," if a software key which
does not correspond to the setup is entered, the setup of "20" is
changed to "1."