(AR-287/337/407/507)
Used to adjust the lead edge by entering the lead edge shift on each
lead edge of 400% copy.
Descriptions on adjustment items
A. Distance from the image lead edge to 10mm of the scale (Platen
400%) (L1)
B. Distance from the paper lead edge to the image lead edge (L2)
C. IMAGE LOSS
D. DEN-A
E. DEN-B
Adjustment procedures
1. Set the image loss quantity (IMAGE LOSS) and the paper lead
edge void quantity (DEN-A) to desired values. (0 – 99:
0.1mm/step)
2. Set L1/L2 to 0.
3. Make a 400% copy with OC, and enter the shift quantity to L1/L2.
(0 – 999: 0.1mm/step)
4. Repeat procedure 3 so that the paper lead edge void quantity of
the actual copy image becomes the set value of procedure 1.
5. Adjust the rear edge void quantity (DEN_B). (0 – 99: 0.1mm/step)
50 - 5
Purpose
Adjustment
Function
(Purpose)
Used to adjust the print image position (top margin) on
the print paper in the print mode.
Item
Picture quality
Print area
Operation/
Procedure
1. Enter the adjustment value with the 10-key.
2. Press the [EXECUTE] key to set the adjustment
value entered in procedure 1.
When the set value is increased, the top margin is increased.
When the set value is changed by 1, the top margin is changed
by about 0.1mm.
Default: 50
50 - 6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy lead edge. (RSPF)
(AR-501/505/507)
Item
Picture quality
Print area
Operation/
Procedure
1. Perform the 0C lead edge adjustment with SIM 60-
1/2. (To use the 0C lead edge void quantity.)
2. Set the image loss quantity (LOSS (RSPF)) to a desired value. (0 -
99: 0.1 mm/step)
3. Adjust the original scanning start position (RSPF (SIDE1)/RSPF
(SIDE2)) so that the actual copy image loss quantity is as speci-
fied in procedure 2. (0 - 99: 0.1 mm/step)
4. Adjust the rear edge void quantity (DEN-B). (0 - 99: 0.1 mm/step)
5. Adjust the rear edge image loss quantity (REAR LOSS (SPF))
when the SPF is used. (0 - 20 mm/step)
There are five input items of the copy lead edge adjustment; LOSS
(RSPF), RSPF (SIDE1), RSPF (SIDE 2), DEN-B, and REAR LOSS
(RSPF). Select the desired item with [
], [
¯
] keys to change the set
value.
1. Image loss quantity setup value (RSPF ) --- (LOSS (RSPF))
Used to adjust the output timing of the image lead edge signal
(SCAN signal) after starting scanning of the original. (0 - 99: Ref-
erence value 20)
2. Original front surface scanning start position adjustment value ---
(RSPF (SIDE1))
Used to set the time from the start of original feed to reaching at
the exposure position. ([Front surface] (0 - 99: Reference value
50)
3. Original back surface scanning start position adjustment value ---
(RSPF (SIDE2))
Used to set the time from the start of original feed to reaching at
the exposure position. [Back surface] (0 - 99: Reference value 50)
4. Rear edge void quantity adjustment value --- (DEN-B)
Used to set the void quantity made at the rear edge of the original
when the RSPF is used. (0 - 99: Reference value 30)
5. Rear edge image loss quantity setup value --- (REARL LOSS
(RSPF))
Used to set the image loss quantity at the rear edge when the
RSPF is used. (0 - 20: Reference value 0)