When the copy image is longer than the original, move in
the direction of B.
·
When the copy image is shorter than the original, move in
the direction of A.
·
One scale of scribe line corresponds to 0.2%.
·
For fine errors which cannot be adjusted with this adjust-
ment, use the next simulation SIM 48-1.
(6) Main/sub scanning direction magnification ratio
adjustment
1) Before this adjustment, perform the previous adjustment of CCD
unit installation position.
2) Place a scale on the original table as shown. (Scale a and scale b
may be placed together or individually.)
·
After warming up, the ready lamp lights up.
·
The current set value is displayed simultaneously. (0
~
20)
illust: AR-280
3) Make a normal copy and obtain the main/sub scanning direction
magnification ratios.
Copy magnification ratio (MRCP)
=
(
Original
dimension
– Copy dimension
)
Original dimension
´
100%
4) Execute SIM 48-1.
(AR-501/505/507)
(Other models)
5) Change value A so that the magnification ratio in the sub scanning
direction is within the specified range.
6) Change value B so that the magnification ratio in the main scan-
ning direction is within the specified range.
·
Adjustment specification: Within
±
0.8%
·
When the copy dimension is smaller than the original
¯
Make the value greater.
·
When the copy dimension is greater than the original
¯
Make the value smaller.
When the value is changed by one step, the ratio is changed
by about 0.1%.
[AR-280/281 only]
7) Make a copy of A3 original with SPF, and measure the magnifica-
tion ratio in the sub scanning direction.
8) Change value C so that the magnification ratio in the sub scanning
direction is within the specified range.
9) Press the CA key to cancel the simulation.
10
20
30
40
50
60
70
80
90
50
10
0
110
120
130
140
10
20
30 40 50 60 70
80 90
50 100 110 120 130 140
Scale a
Scale b
10
20
90
100
110
10
20
90
100
110
10
20
90
100
110
Scale
(Original)
(Example 1)
Copy A
(Shorter than
the original)
(Example 2)
Copy B
(Longer than
the original)
Paper exit direction
a > Magnification ratio in the main scann ing direction
b > Magnification ratio in the sub scanning direction
6 – 13