26 - 40
Purpose
Setting
Function
(Purpose)
Polygon motor stop mode setup (AR-501/505/507)
Used to set the stop time of the polygon motor after
leaving in ready state and to set Enable/Disable of the
setting. (Other models)
Item
Specifications
Operation/
Procedure
(AR-501/505/507)
When this simulation is executed, the current set value
is displayed.
At that time, the set value can be changed with the 10-key.
When the OK key is pressed, the currently set value is stored in the
EEPROM.
Default: 0
0
Normal mode
Control according to the setup in the
silent mode by the user setup.
1
Silent mode
After completion of a job, the polygon
motor is stopped in the time set in the
silent mode of the user setup.
(Other models)
A:
1. Used to set the time (minute) to stop the polygon motor with the
10-key.
(Regardless of setting in B, the time can be freely set.)
2. Press the OK key to store the set time.
3. Press the CA key to reset. Only when B is set to "1: YES", the
polygon motor is stopped in the set time.
Set range: 1-30 min
Default: 30 min
B Used to set YES/NO of the setup of A.
Default: 0 (NO)
Set value
Content
0
NO (The currently set operation is performed.)
®
SP/FP does not stop.
40 NEW Stops in the default time (30 min).
1
Stops in the set value of A.
26 - 41
Purpose
Setting
Function
(Purpose)
Used to enable/disable the auto magnification ratio se-
lect (AMS) function in the pamphlet copy mode.
Item
Specifications
Operation mode
(Common)
Operation/
Procedure
This simulation is used to enable or disable the auto-
matic magnification ratio selection (AMS) in the pam-
phlet mode.
Set value
Set content
0
Automatic magnification ratio selection (AMS) is
enabled.
1
Automatic magnification ratio selection (AMS) is
disabled.
26 - 44
Purpose
Setting
Function
(Purpose)
Used to set the model of the unit which is connected to
the SCSI I/F of ICU PWB.
Section
ICU
Item
Specifications
Interface/Communication
Operation/
Procedure
(AR-250/280/281/285/286/335/336/405/501/505)
A is at the left of B when viewed from the rear side.
0: No connection
1: Printer controller
3: External printer controller (Not used)
4: Scanner controller (Not used)
8: Tandem connection (Initiator)
10: Tandem connection (Target)
Two SCSI channels available
(AR-501/505)
(Other models)