60
60 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation (read/write) of ICU
(DRAM). (SIMM MEMORY/ONBOARD MEMORY)
Section
ICU
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key to check the read/write
operations.
2. After completion of the read/write operation check, the check re-
sult is displayed with OK or NG.
61
61 - 1
Purpose
Operation test/check
Function
(Purpose)
Used to test the operation of the scanner (exposure)
unit.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
1. Press the [EXECUTE] key
The scanner unit is started.
2. After completion of check operation, the result is displayed with
OK or NG.
Used to check whether the sync signal (HSYNC/) is normally out-
putted or not by operating the laser (exposure) unit (laser motor
rotation, laser emission).
61 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjust the scanner (exposure) laser power (ab-
solute value) in the copy mode.
Section
Laser (Exposure)
Item
Operation
Operation/
Procedure
(AR-230/280/285/335 series)
All must be set to "16."
(AR-281/250/286/336)
Set all to "7" except for PH256.
(AR-287/337)
All must be set to "8".
(AR-405)
Set all to "5" except for PH256.
(AR-407)
All must be set to "6".
7/13/2000
7 – 51