5. Press the [MIN POSITION] key.
6. Press the [EXECUTE] key.
The key is highlighted then it returns to the normal display.
The manual paper feed guide min. position detection level is rec-
ognized.
If the above operation is not performed properly, the ERROR display
is highlighted.
If performed properly, the above data is stored and the COMPLETE is
highlighted.
41
41 - 1
Purpose
Operation test/check/Operation data output/Check (Dis-
play/Print)
Function
(Purpose)
Used to check the operation of the document size sen-
sor and the related circuit. (The operation of the docu-
ment size sensor can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The operations of the sensors and detectors in the
document size detection section are displayed.
The active sensors and detectors are highlighted.
OCSW Document
cover state
Normal display:
Open
Highlighted display:
Close
PD*
Document
sensor
Normal display:
Document empty
Highlighted display:
Document exist
AB series
Inch series
41 - 2
Purpose
Adjustment
Function
(Purpose)
Used to adjsut the document size sensor detection
level.
Section
Others
Item
Operation
Operation/
Procedure
1. Press [1 NO ORIGINAL] key, open the document
cover, and press [EXECUTE] key without a docu-
ment on the document table. The sensor level set-
ting with no original on the table is performed.
(Normal case) The COMPLETE display is highlighted (for 1 sec),
then it returns to the normal display.
(Abnormal case) The INCOMPLETE display and the abnormal
sensor name are highlighted.
2. Set an A3 paper (11" x 17") and press the [EXECUTE] key. The
sensor level setting with original is performed.
(Normal case)
The COMPLETE display is highlighted (for 1 sec), then it re-
turns to the normal display. The "A3 ORIGINAL" display turns
to "NO ORIGINAL" .
(Abnormal case)
The INCOMPLETE display and the abnormal sensor names
are highlighted.
41 - 3
Purpose
Operation test/check
Function
(Purpose)
Used to check the operation of the document size sen-
sor and the related circuit. (The document size sensor
output level can be monitored with the LCD.)
Section
Others
Item
Operation
Operation/
Procedure
The detection output level of each sensor is displayed
in real time.
OCSW
Document cover state
PD*
Document sensor
*
The value in [ ] shown at the right of each sensor name is the
threshold value.
7/13/2000