![Servomex SERVOPRO FID Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/servomex/servopro-fid/servopro-fid_operators-manual_1247061030.webp)
SERVOPRO FID Online Total Hydrocarbons Analyser
SERVOPRO FID 01000001A rev:5 28
control output.
Sample flow
cc/min
0-200
Actual sample flow.
Sample
pressure
PSI
0-100
Actual sample pressure.
Sample
counts
Counts
0-65535
Actual sample sensor signal.
Sample output %
0-100
Actual sample pressure regulator
control output.
FID
temperature
Celsius
Actual FID. temperature
FID counts
Counts
0-16777216
Actual FID. temperature sensor’s
signal.
FID output
%
0-100
The power of the FID heater.
Chrom signal
Volts
0-5
Actual detector signal.
Chrom signal
count
Counts
0-16777216
Actual detector signal.
UI v
User interface software version.
IO Board v
IO Board software version.
Smp v.
Sample pressure regulator software
version.
Air v.
Air pressure regulator software
version.
Fuel v.
Fuel pressure regulator software
version.
Last
maintenance
Date of the last maintenance.
Serial number
Serial number of analyser.
Table 18 : Diagnostic parameters
The alarm historic menu is used to report alarms and system errors. Every time an
alarm or an error occurs, a message is displayed with the time and date. When the
error is resolved, the same message is displayed with time and date as well as:
OK. For example if a flame off occurs and then the error is resolved, flame off:ok
will be displayed.