Establish a system height (distance from the floor to the system run) that allows adequate clearance from
obstructions and maximizes the desired viewing area. The rail must be hung a minimum of 2.5 meters above
the floor at its lowest point. Verify at least 0.3 meter of clearance, from the top of the rail section down, over
the entire proposed system run.
NOTE
Local codes may dictate different specific
distance requirements .
Power for the CurveTrack® systems should be controlled by dedicated circuit breakers. There should be no
more than four CurveTrack® Power Supplies (i.e. four system runs) per circuit breaker.
Ensure that floor level obstructions to lift equipment, ladders, etc. are
accounted for and can be worked around to maintain a safe environment for
installation workers and bystanders. Be especially aware of the potential hazard
of falling materials, tools and debris as well as potential trip hazards, including
power cords, in areas below the installation zone.
DANGER
All CurveTrack® equipment and installation materials that are at the site of the installation must be inspected
for damage. All Claims for losses, or damage to the system in transit, must be made with the carrier. Packing slip
documentation should be checked carefully against material received to ensure that everything that is needed
has arrived. It is suggested that before the actual construction begins, the installation team do a complete
inventory while the lead installer reviews the site. Any shortages in parts or materials must be reported as soon
as possible so that corrections can be made in a timely fashion.
After inspection, return all materials to their shipping containers to protect them until they are used. Designate
a specific storage area in a protected place to prevent accidental damage, especially to delicate electronic parts
and the easily – damaged windows.
3.4 Material inspection and inventory
3.5 Material storage