The Universal Configuration Module
Senstar LM100 Product Guide
Page 47
Configuration parameter
Descriptions
Address
Use the
Address
button to assign Silver Network based Senstar
LM100 gateway’s a unique network address (1 - 60)
Application
Use the
Application
button to update the LM100 gateway, luminaire,
or wireless gate sensor firmware
Device Time
Use the Clock button to reset the gateway time to the current time
setting of the UCM computer.
Config tab - sensor head configuration, settings apply to luminaires, see
Comm Channel
If 2 or more Senstar LM100 systems operate within 400 m (1300 ft.)
of each other, they must use different
Comm Channels
to prevent
mutual interference (1 - 16)
Lights sub-panel - sensor head lighting configuration
Target Filter (Hz)
There are 2
Target Filters
for adjusting the frequency response of
the luminaires (2 - 400 Hz)
The high pass filter is used to screen out low frequency vibrations
such as wind sway (the fence motion caused by wind and loose
fence fabric)
The low pass filter is used to screen out high frequency vibrations
such as the thermal expansion and contraction of palisade fences
Event Window (sec)
Sets the wait time period after an Event is recorded before the next
Event can be recorded (0.5 - 10 seconds)
Used to prevent vibrations caused by a single Event from being
recorded as subsequent Events
Event Count
When the detection signal exceeds the Threshold setting an Event is
recorded and added to the
Event Count
;
When the number of recorded Events reaches the
Event Count
setting an alarm is declared (1 - 10)
Alarm Window (sec)
Sets the time period after an Event is recorded in which the next
Event must occur (1 - 99 seconds)
Each time the
Event Count
is incremented, the
Alarm Window
time
is reset and begins to count down from the specified value;
If a subsequent Event occurs before the
Alarm Window
time lapses
the
Event Count
is incremented and the
Alarm Window
time is reset
and begins to count down from the specified value;
If the
Event Count
setting is reached before the
Alarm Window
time
expires, a sensor alarm is declared;
The
Alarm Window
resets after each Event;
If the
Alarm Window
time lapses before a subsequent Event is
recorded both the
Alarm Window
and the
Event Count
are reset
Supervision tolerance
Sets the level of change in orientation that will cause a supervision
alarm (1x, 2x, 4x, 8x).
Level 1 Light Control - set the luminaire brightness for scheduled operation, fourth priority
Light Level
Set the
Light Level
(brightness) for scheduled Level 1 light activation
Level 2 Light Control - set the luminaire brightness for scheduled operation, third priority, overrides
Level 1 Light Control
Light Level
Set the
Light Level
(brightness) for scheduled Level 2 light activation
Alarm Light Control - set the luminaire response to alarm conditions, second priority, overrides
Level 1 and Level 2 Light Control
Mode
Specify the luminaire’s lighting activity in response to a sensor alarm
(e.g., strobe the luminaire that recorded the alarm and activate all
other luminaires that are assigned to the same zone)