Input configuration procedure
1.
Select the Aux Cfig tab on the UCM window.
2.
Use the Input: arrows to select an input to configure.
3.
From the Supervision drop down, select the desired supervision scheme for the input.
4.
Select the Resistor 1 value, if applicable.
5.
Select the Resistor 2 value, if applicable.
6.
Set the Noise Tolerance, if required.
7.
Set the Line Drop, if required.
8.
Set the Filter Window.
9.
For Local Control mode, specify the luminaire zone to activate when the input is activated.
10. Select the Light Level (brightness) for the activated zone.
11. Repeat this procedure for each designated input.
12. Save the UCM configuration file and download the configuration changes to the gateway.
Input option
UCM selection
Alarm relay Supervision
R1
R2
unsupervised
NO
---
---
---
single resistor
supervision
NO
cut
5.1 k
---
dual resistor
supervision
NO
cut & short
4.3 k
820
unsupervised
NC
---
---
---
single resistor
supervision
NC
short
5.1 k
---
dual resistor
supervision
NC
cut & short
5.1 k
820
Table 2: Selectable input configurations
R1 values (single resistor
supervision)
R1 values (double resistor
supervision)
R2 values (double resistor
supervision)
820
1.1 k
820
1 k
2.2 k
1.1 k
1.1 k
4.3 k
2.2 k
1.2 k
4.7 k
3.3 k
1.5 k
5.1 k
5.6 k
2.2 k
5.6 k
3.3 k
4.7 k
5.1 k
5.6 k
Table 3: Selectable resistor values
A
1
A
S
1
2
A
S
A
1
2
A