Equipment layout
Senstar LM100 Product Guide
Page 19
Equipment layout
Depending on the height of the fence and the desired level of security, a luminaire is attached to
every fence post (3 m spacing) or every second fence post (6 m spacing). Regardless of the
luminaire spacing used, each tension post, corner post and gate support post, should have a
luminaire attached as these types of posts are usually made of thicker steel and have a wider
outside diameter (OD) than regular fence posts. As a result of the heavier construction, these
posts tend to dampen vibrations.
Use a site plan to mark the locations for the Senstar LM100 components:
•
LM100 gateway - indicate the location and note the address for network based systems
•
LM100 luminaire AP - indicate the location for the Access Point
•
LM100 luminaires - indicate the location, the segment groupings, and zone boundaries (on the
site plan, number the luminaires in the order that will be used to form segments)
•
Power supply - indicate the type and capacity of power supply and the power distribution plan
•
Power cable - indicate the type and length of power cables that will be used
•
Alarm communication wiring - relay output or network alarm communications; indicate the type
and length of data cables
•
Wireless Gate Sensor - the number of protected gates and the number of WGSs required to
cover them
Figure 9: Example site plan
LM1_AP
power cable routing
LM2
LM3
LM4
LM5
LM6
LM7
LM8
LM9
LM10
LM11
LM12
LM13
LM14
LM15
LM16
LM17
LM18
LM19
LM20
LM21
LM22
LM23
LM24
LM25
LM26
LM27
LM28
LM29
LM30
LM31
LM32
LM33
LM36
LM37
LM38
LM39
LM40
LM41
LM42
LM43
GW
WGS1
WGS2
WGS3 WGS4
security
control
room
parking
buried conduit
(power & RS-422)
buried
(power)
3m post spacing 6m luminaire spacing
shipping gate
StarNet 2 SMS
network
power supply
loading dock
outdoor alarm and lighting zones
Zone 1: LM1 - LM6 & LM9
Zone 2: LM7, LM8 shipping gate
Zone 3: LM10 - LM16 North fence
Zone 4: LM17 - LM23 East fence
Zone 5: LM24, LM25, LM28, LM29 South fence
Zone 6: LM26, LM27 main gate
Zone 7: LM30 - LM43 (facility outdoor lighting)
Zone 8: WGS1 East panel main gate
Zone 9: WGS2 West panel main gate
Zone 10: WGS 3 South panel shipping gate
Zone 11: WGS4 North panel shipping gate
conduit
main
gate
LM34
LM35