![SENSTAR LM100 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/senstar/lm100/lm100_product-manual_1244244064.webp)
Scheduling routine light activation
Page 64
Senstar LM100 Product Guide
Scheduling routine light activation
Once the segment and zone assignments are made, a schedule can be setup for routine light
control. The Senstar LM100 enables up to eight lighting schedules for the defined luminaire zones.
Specify the time at which the schedule begins (On) the time at which the schedule ends (Off) the
days of the week on which the schedule is active, the Zone to which the schedule applies, and set
the brightness (Level) on the Schedule tab.
Scheduling routine luminaire activation
1.
On the Config tab Lights sub-panel, use the Light Level sliders to set the brightness of the
luminaires that will be activated by the schedule.
2.
Select the Schedule tab and select (check) the first scheduling checkbox.
3.
Set the time at which the schedule will begin (On).
4.
Set the time at which the schedule will end (Off).
5.
Choose the days of the week on which the schedule will be active.
6.
Choose the luminaire zone that will follow the schedule (select All if the schedule applies to all
installed luminaires).
7.
Select the brightness Level for the schedule (Level 1, Level 2 or force Off).
8.
Save the UCM file and download the configuration changes to the Senstar LM100 gateway.
Note
To use a schedule to disable the lights, set the Level to Off.
The light level (brightness) for Level 1, Level 2 and Alarm light control
are configured on the Lights sub-panel.
Figure 58: Setting routine scheduled light activation
select a checkbox to setup a
set the time at which the lights
routine lighting schedule
turn On and Off
select the days of the week
specify the zone to activate
(select All to activate all
installed luminaires)
specify the lights priority Level
(schedule 1 disables all luminaire
lights during daylight hours)
(brightness)