System description
Page 12
Senstar LM100 Product Guide
The Universal Configuration Module
The Universal Configuration Module (UCM) is a Windows based software application, which
serves as the calibration, setup and maintenance tool for the Senstar LM100 system. The UCM
communicates with the gateway locally through a USB connection, or remotely via the Silver
Network Manager. When the UCM software starts, a window displays that enables you to specify
the device to which you are connecting (Senstar LM100).
Alarm communication options
•
contact closure alarm communications provide up to 14 distinct alarm zones per Senstar
LM100 system (requires optional relay output card)
•
Silver Network data communications using RS-422 copper wire data paths, Ethernet cable, or
fiber optic cable (requires a network interface card)
Relay Output Card
The relay output card (ROC) (P/N 00BA2500) includes four relays to supplement the outputs
available on the gateway. In local control mode, the ROC’s outputs signal user-selectable alarm
and supervision conditions. In remote control mode, the host security management system
operates the ROC’s relays as output control points. The ROC’s outputs cannot source power. The
ROC is mounted on the gateway’s expansion header.
Dry Contact Input Card
The dry contact input card (DRIC) (P/N 00BA2400) includes four inputs to supplement the inputs
available on the gateway. In local control mode the DRIC’s inputs are used to activate user-
specified luminaires. In remote control mode, the inputs report the status of auxiliary devices to the
host security management system. Inputs to the DRIC must be voltage free. The DRIC is mounted
on the gateway’s expansion header.
Figure 3: Senstar LM100/
Wi-Fi
overlapping frequencies