![SDKELI KS06 AOPD Series Скачать руководство пользователя страница 60](http://html1.mh-extra.com/html/sdkeli/ks06-aopd-series/ks06-aopd-series_operation-manual_1220444060.webp)
- 56 -
4.2.Inspection for the guarded machine
□The hazardous parts are movable when nothing is in the detection zone.
□The hazardous parts stop immediately when a test piece is inserted into the detection zone.
□The hazardous parts remain stopped as long as the test piece is in the detection zone.
□The hazardous parts stop when the power of the KS06 is turned OFF while nothing is in the detection
zone.
□The machine itself does not prevent the operation of safety functions such as stopping.
4.3.Items to inspect every 6 months or when machine settings are changed
In addition to inspection items in 4.1 and 4.2, following items must also be verified.
□The outputs of KS06 and the machine are properly wired.
□The total number of times that the control relays/contactors have switched is significantly lower than their
design lives.
□There is no interference light.
□The cables must not be bent, cracked, nor damaged.
□KS06 is fixed fasten, no loose.
□The changing of machine setting affects the safety of the control system.