![SDKELI KS06 AOPD Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/sdkeli/ks06-aopd-series/ks06-aopd-series_operation-manual_1220444058.webp)
- 54 -
5. Ensure that the safety distance and relative altitude height are both correct.
6. Fasten firmly all the installed screws on AOPD.
2)angle adjustment of muting function
If muting function needs to be realized, the angle of cam can be adjusted according to the situation
shown in Fig4.1 on the premise of safety. In the case that muting function is realized with the help of
AOPD, the state of muting function is shown in Sheet3.1.
Fig 3.2 Structure & functional mode of cam switch
Sheet 3.1 State of muting function
State of cam
switch
State of light
curtain
Indicator of receiver
Indicator State of controller
State of stop
control loop
Green
Red
Normal operation
Unusual station
Closing
Unblocked
ON
OFF
ON
OFF
Closing
Blocked
OFF
ON
OFF
ON
Closing
Opening
Unblocked
ON
OFF
ON
OFF
Closing
Blocked
OFF
ON
OFF
ON
Opening
3) Commissioning
After debugging, commissioning should be carried out to ensure the AOPD is absolutely risk-free in
operation.
1. Shade the light beams of light curtain, observe indicators of AOPD, and check if the conversion of
indicators is in line with status in sheet 3.1.
2. For presses on which the slider can stop at any position in one stroke, in the protection interval for the
machine with muting function, the cam switch of muting function is in opening status from 30° to 180° of
stroke down shade the light curtain, the slider will stop at once.
WARNING
For presses on which the slide can stop at any point in one stroke, the braking must not have any
failure!
If the braking is at fault, the machine must be repaired!
If the braking of machine is at fault, the safety of AOPD is at risk
!
For presses which can only realize upper dead point protection, when the slider is at the upper dead
point, shade the light curtain, the next stoke is not able to start up.
WARNING
For presses on which the slide can stop at any point in one stroke, the braking must not have any
failure!
If the braking is at fault, the machine must be repaired!
If the braking of machine is at fault, the safety of AOPD is at risk
!
When the slider is at the lower dead point, shade the light curtain, the slider should be able to return.
If 1.2.3 above are all met, the debugging of AOPD is successful, and it can be put into use.