- 34 -
Fig 2.5.C Set up isolation devices between systems to eliminate interference
2.2 Installation
2.2.1 Mutual interference prevention
Installation of CPS
Ⅱ
controller:
CPSII is installed on the bed support of machine through
controller support, the procedures are as follows:
A. Select proper position according to the external dimensions
of the controller.
B. According to the mounting dimensions of controller support,
fix the support well, as shown in Fig2.6.
C. Install the controller on the support through shock absorber
and its bowl, the procedures are as follows:
● Take off two shock absorbers from the upper part of the
support, and then put them into the shock
absorber bowl of the upper part of controller.
● Aim the shock absorber bowl of the lower part of the
controller at the shock absorbers of the lower part the support,
and then assemble the shock absorber and its bowl. Push
forward the controller into its support; make the tapped holes
of shock absorbers to be aimed at the holes of the upper part of
the support.
● Tighten the M5×10 cross recessed screws to fix firmly the
two shock absorbers to the upper part of the support.
Fig 2.6 Controller supportt
Installation of CQ2 controller:
Fig 2.7 CQ2 controller