Correct operating position (plan view)
Other risks and dangers
There are some moveable elements on the machine, which can cause injuries of hands or fingers. For reasons of workability, these
elements cannot be eliminated. They can cause injuries / mash fingers or hands. It is important to work with the machine with great care
and be alert to avoid other dangerous situations. The machine should be operated in accordance with the manufacturers recommendations
to avoid risks. The machine complies with the essential requirements laid down in regulation for machines. Above information has been
worked out in accordance with the standards PN-EN 12100:2012. The machine is constantly upgraded in order to improve its safety. All
comments regarding the contents of this manual can be addressed to the distributor or manufacturer.
2
. Initiation
2.1 Notes regarding transportation
Because of the large dimensions of the machine, the PRETREATmaker LINE is delivered, installed and assembled by the manufacturer
(service).
2.2 Warranty terms and conditions
The machine has to be operated with a precoating liquid for fabrics, to prepare them for DTG printing. Cleaning must be done with destilled
water only. Other liquids may damage pumps or other components of the machine. Damages caused by unauthorized liquids are excluded
from the warranty. The PRETREATmaker Line comes with a 12 months warranty. This warranty includes the whole construction of the
machine, mechanical parts, electronics, drawer with rails, casing, pumps electronic valve and pipes. Consumption items such as
brass/stainless steel nozzles, silicon foam, safety covers, seals and filters are excluded from the warranty. Thermo fuses, temperature
sensors, switches and buttons and all springs in the machines have a warranty of 6 months.
2.3 Supply voltage
The PRETREATmaker LINE has to be connected to a voltage of 400VAC/50Hz. The machine is equipped with a power plug. Make sure
thet the power outlet is in the right condition and that the grounding is connected to the power outlet.
Caution: please do not connect this press to any other outlet (socket) than those equipped with ground-fault protection ELCB (earth
leakage circuit breaker). In case of doubt ask your licensed electrician to check the wiring. Connecting the machine to a socket that is not
earthed or where the earthing does not work properly, is hazardous to health and dangerous for the machine. Any damages arising from
an improper plugging invalidated the warranty.
2.4 Connecting the machine to the compressor
PRETREATmaker Line is a pneumatic device, which needs to be connected to a compressed air system. Optimal pressure for correct
work shouldn’t exceed 6 bar. The air supplied to the machine needs to be dry and without oil. If needed use an additional filter and
dessicator. The air compressor is connected with a connector type 26 eurostandard
(picture 1).
After finishing work disconnect the
compressed air and drain the filter. If the compressed air system has no additional dessicator, the container needs to be checked every 4
hours during operating sequence. If needed it can be emptied by twisting the little valve off
(picture 2).
If there is oil in the container
besides water, the air compressor is working faultily. In this case the machine has to be shut down and the compressor needs to be
repaired. The oil from the compressor can damage the pneumatic valves in the machine. If needed,contact the service for help.
Version 18.04