4.2 Periodic maintenance
Before performing any maintenance work, turn off the machine, disconnect it from the electricity and wait till it gets cold.
Clean
the carriage rails and the teflon holder once a month using WD40. To clean the carriage and teflon holder/slider, unscrew the fixing screw
of the covering rail and remove it
(pictures 1 – 2)
. After cleaning of the carriage rails, the teflon holder and the belt
(zdjęcie 3)
put the
covering rail back and screw the fixing screw on. It is recommended to grease the main driver once a month using a brush and a
waterproof grease, for example CX-80
(picture 4)
. It is also recommended to grease the contact screws which are situated under the
base plates
(picture 5).
The chamber of the exhaust ventilator should be controlled once a month
(pictures 6 – 7)
and cleaned when
necessary
(picture 8).
Once a month the separator has to be controlled and emptied when needed
(pictures 9 – 10).
The carriage’s filter should be cleaned at
least once a month
(pictures 11 – 13).