4.3 Side cover’s sensors adjustment (pretreatment station)
The side cover’s sensors are situated on the pneumatic cylinder in the lower part of the pretreatment station
(picture 1).
They are equipped
with a diodes
(picture 2).
During normal operation, the upper diode should glow when the side cover is closed
(pictures 3-4).
When the base
plate with a t-shirt will move to the pretreatment station, the application of precoatng will start automatically. If the side cover will not close, or
the sensor will be moved or damaged, the application of precoating will not start. If the side cover is closed, but the cycle does not start, the
position of the upper sensor has to be adjusted. In order to do this, the fastening screw has to be loosen
(picture 5)
. Move the sensor down,
to the middle of the cylinder length and then move it up till the diode will glow. Then move the sensor for another 5 mm up and fasten it with a
screw.
The lower diode should glow when the side cover is open
(pictures 6-7).
When the side cover will open, the base plates will move to the
right. If the plates will not move after the side cover will open, the signal tower will light red and an error message will appear on the
touchscreen (PRE 4 4-covers up time err – READY Move Tab), it has to be checked if the diode on the lower sensor glows. If not, the
position of lower sensor has to be adjusted. In order to do this, the fastening screw has to be loosen
(picture 8).
Move the sensor down and
then up till the diode glows. Then fasten the sensor with a screw.