2.5 Preparation the machine for operation
Before start to work with the machine, make sure that all the covers are assembled and connected to the machine. The device may be
operated by a person trained and acquainted with the service manual. After removing the unit from the pallet and remove the protective
film should be mounted nozzles. The nozzles are attached to the machine with the power cord, filter and washer. The nozzles must be put
together and installed into the machine
(pictures below).
Fumes escaping from the pretreatment machine will condense and discharge to the separator. The separator needs to be connected to the
machine
(pictures 1-2)
.
Before starting to work with the machine the drip trays have to be placed in the designated spaces.
Before switching the machine on, check whether the protective cable is correctly connected. All containers should be controlled before
starting operations. The container with precoating liquid should be shaken everyday. Make sure that the deposit tank is empty and properly
connected.
1. Fill the water container with distilled water.
2. Fill the precoatinhg containers up with the liquid. The containers must be shaken every day.
3. Make sure the waste-water container is empty
4. Take the nozzles off.
5. Turn the machine on.
6. Turn the precoating button on the touch screen display and hold it until the precoating liquid starts flowing from the nozzles.
7. Turn the first nozzle on the left on and press the precoating button on the touch screen display again.
8. Turn the first nozzle off and the second one – on. Press the precoating button on the touch screen display again.
9. Proceed with the nozzles 3,4, and 5 in similiar way. This process removes air bubbles from the ducts.