Operating manual 810378-BAL-EN-170330
Mach/30 2017
Page 14 of 54
4.1.3.
HV-supply with integrated discharger
High-voltage output
Cable is cast in insulation grease
and must be installed/replaced in
the factory
LED supply
LED Ethernet status
LED HV status
Discharger connection
Network
M12 connection
4-pin socket D-cod.
Drive supply and monitoring
contact
M12 connection
5-pole B-coded plug
Ground connection
M6 threaded bolts
High-voltage connection
Connection between genera-
tor and discharger must only
be replaced in the factory