Operating manual 810378-BAL-EN-170330
Mach/30 2017
Page 42 of 54
2
0
I
max
switch off
1: Imax switch off
0: No error or error acknowledged
1
U
min
switch off
1: Umin switch off
0: No error or error acknowledged
2
Electrical arc switch off
1: Electrical arc detected and switched
off
0: No error or error acknowledged
3
Over-voltage switch off
1: An actual value above 109 kV has
been detected
0: No error or error acknowledged
4
Communication error display
1: Heartbeat disappeared
0: no error or error acknowledged
5
Missing DRIVE power (when HV
on)
1: 24V DRIVE is not on and HV ON
has been set
0: No error or error acknowledged
6
HV ON specification during relay
test
1: HV ON was set during activated
relay test (HV remains off).
0: No error or error acknowledged
(V2.01 and higher)
7
Power loss too high
1: Output power too low in relationship
to the input power
0: No error or error acknowledged
3
0
Reserve
1
Reserve
2
Reserve
3
Reserve
4
Reserve
5
Reserve
6
Reserve
7
Self-test
1: Self-test of the HV-supply malfunc-
tion (program check sum, internal
hardware, current measurement*)
0: No error or error acknowledged
* The check of the current measurement occurs when switching on the device (24V
CPU on), also for each high voltage switch off.