Operating manual 810378-BAL-EN-170330
Mach/30 2017
Page 24 of 54
Operation
7.
Before operating, the following safety instructions must be read through carefully and
must be understood:
7.1. Safety instructions for operation, service and repair
General information:
A deviation from the conditions for the above mentioned intended use is not
permitted.
Furthermore the operating manual of the surrounding installation must be ob-
served.
The system must be operated by trained personnel.
The employees must be informed at specific intervals about accident prevention
regulations and operating instructions.
During repair and service of the surrounding system the conditions for normal
use of the HV generator apply.
Never work on systems that are under high-voltage.
Specific instructions:
The housing of the high-voltage generator is also used for cooling.
Therefore the housing should be kept clean.
Never operate the device if it is defective, damaged or opened.
Specific repair instructions:
If the generator
must be uninstalled for repair,
we recommend disconnecting the
signals in the following sequence:
1. Disconnect M12 CAN bus connection.
2. Disconnect M12 power supply connection.
3. Disconnect HV connection.
4. Disconnect ground connection.
WARNING
Do not open, plug-in or unplug connections under live
voltage.
WARNING
During the deinstallation of an HV generator, parts which are
voltage carrying in operation must not be touched if they are
not grounded with a grounding rod BEFORE the grounding
connection of the HV generator is disconnected!
This must especially be observed with defective HV
generators!
CAUTION
The high-voltage should be switched off before disconnecting
the 24V current wire. Exception: Emergency situations
The HV generator contains no parts to be repaired by the user. It can only be re-
paired by the manufacturer.