5.3.3 Installation Instructions
CAUTION
Incorrectly connected operating voltage or signal plug
Material damage to the system
►
The system must only be operated at the operating voltages specified for the
respective components. Electrical connections must use the original
connection cables and be in accordance with the circuit diagram (see
appendix).
Attaching the vertical beams:
1. Use a suitable lifting device to place each of
the side beams (11) onto the industrial truck's
chassis until the drill holes line up.
2. Guide two flat bars into the top of each beam.
3. Insert screws and tighten them until contact is
made.
4. Do not tighten the screws at full torque until
you have positioned the base frame.
Mount according to drawing 11.05.05.00057
(see appendix)
Attaching the base frame:
1. Use the included sling to raise the base
frame to the height of the connection points
on the two beams.
2. Pull the signal and voltage supply wires
through the intended holes.
3. Align the system over the flange plates.
4. Attach 4 screws to each flange using the
corresponding nuts.
Use a tightening torque of 86 Nm.
Then
tighten the counter nut.
Содержание JumboPicker-Flex
Страница 56: ...56 EN www schmalz com 30 30 01 01183 00 Appendix Design Drawings and Bill of Material...
Страница 57: ...30 30 01 01183 00 www schmalz com EN 57...
Страница 58: ...58 EN www schmalz com 30 30 01 01183 00...
Страница 67: ...30 30 01 01183 00 www schmalz com EN 67 Drawing JumboFlex 11 05 05 0025...
Страница 69: ...30 30 01 01183 00 www schmalz com EN 69 EC declaration of incorporation...
Страница 70: ...70 EN www schmalz com 30 30 01 01183 00...