30.30.01.01183/00
www.schmalz.com
EN | 51
9.4 Service Table
This maintenance interval overview applies for single-shift operation. The inspection intervals may
have to be shortened in the case of higher loads.
Interval
Daily
Weekly Monthly
Every
six
months
Annual
check
Vacuum generation
Check carbon vane and integrated filter
X
Clean additional filter
X
X
Is the electrical installation OK? Are cable screw
unions secure? Are the cables in good condition (not
brittle, not kinked, no worn sections)?
X
Is the supply hose in good condition (not brittle, not
kinked, no worn sections, i.e. not leaking)?
Does the hose need to be untwisted?
X
X
Tube lifter
Is the lift tube in good condition (not porous,
no worn sections, no holes, i.e. not leaking)?
X
X
Is the lift tube attached properly?
(correct position, correctly sealed)
X
Can the rotary union be moved easily?
X
X
Are all connections (hose clamps, etc.) secure?
X
Type plate and maximum load plate attached and
legible.
X
Are the operating instructions still available and are
operators familiar with them?
X
Is the latching bolt secure?
X
Check all load-bearing parts (e.g. suspension of the
Jumbo) for deformation, wear, rust or other damage.
X
X
Check whether the filter is soiled
X
X
Grippers
Is the seal of the tube holder/gripper OK?
X
X
Does the suction cup still fit tightly; and is it working
properly?
Are the sealing lips even? Replace as needed
X
X
Is the filter fleece in the suction cup clean?
X
X
Содержание JumboPicker-Flex
Страница 56: ...56 EN www schmalz com 30 30 01 01183 00 Appendix Design Drawings and Bill of Material...
Страница 57: ...30 30 01 01183 00 www schmalz com EN 57...
Страница 58: ...58 EN www schmalz com 30 30 01 01183 00...
Страница 67: ...30 30 01 01183 00 www schmalz com EN 67 Drawing JumboFlex 11 05 05 0025...
Страница 69: ...30 30 01 01183 00 www schmalz com EN 69 EC declaration of incorporation...
Страница 70: ...70 EN www schmalz com 30 30 01 01183 00...