Page -23-
Interval
Daily
Weekly
Monthly Every six
months
Annual
check
Check all load-bearing parts (e.g. suspension) for deformation, wear or
other damage
X
X
Check the sealing plates or suction
pads for wear, cracks and leaks;
replace if necessary
X
X
Check whether the optional filter fleece is dirty
X
X
Check whether the optional suction pad filter plate is dirty
X
X
General condition of the device
X
Leak test
When the ejector is switched on and the smooth, non-permeable
surface of a workpiece (e.g. a metal plate) is fully picked up, the system
vacuum at the vacuum gauge (see Section 3, Item 5) must indicate a
vacuum that is no more than 20% lower than the maximum possible
vacuum of the ejector used. Example: Ejector reaches max. -0.55 bar.
A vacuum between -0.45 and -0.55 bar must be shown on the gauge.
X
X
Vacuum test
When the ejector is switched on and no workpiece is picked up, the
system vacuum at the vacuum gauge must indicate a vacuum between
-0.20 and -0.4 bar. For the large-area gripper FMP with SVK valve
technology, between -0.35 and -0.5 bar
X
X
Visual inspection of the check valves and flow resistors to see whether
they are contaminated
X
X
Has the dust filter been cleaned? (Fig. 4.3)
X
X
Are the compressed air hoses in good condition (not brittle, not kinked,
no worn sections and no leaks)?
X
X
Is the type plate still on the device?
X
Are the operating instructions still available and are workers familiar
with them?
X
Clean the sealing plate with a soft brush and a vacuum cleaner, and
remove wood chips, dust, etc. Do not blow off with compressed air.
The force of the stream of compressed air would destroy the structure
of the foam
X
Check and adjust connections, screws, etc.
X
Check hose lines and connections for leakage
X
Note: Suspension, compressed air hoses and pressure filters are not part of the FXP device.
Technische Änderungen, Druckfehler und Irrtümer
vorbehalten!
We reserve the right to make technical changes. No
responsibility is taken for printing or other types of errors.