![Schmalz FXC-HD Series Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/schmalz/fxc-hd-series/fxc-hd-series_operating-manual_1212862014.webp)
DE - Bedienungsanleitung
FXC-HD-SW
GB - Operating Manual
30.30.01.00454
Status 07.2013 / Index 0
Seite/Page 12/19
J. Schmalz GmbH
Aacher Straße 29
D - 72293 Glatten
Tel +49 (0) 7443 / 2403 - 0
Fax +49 (0) 7443 / 2403 - 259
www.schmalz.com
[email protected]
Interval
Daily
Weekly
Monthly
Every 6
months
Every 12
months
Inspect load-bearing parts (such as the suspension) for deformation, wear
or other damage
X
X
Inspect the sealing plate for wear, cracks, leaks, etc. and replace the mat
is necessary
X
X
Inspect the optional filter for dirt
X
X
General condition of the gripper
X
Leak test
During operating vacuum generation and with gripper suction area
completely covered with smooth air-impermeable workpiece (e.g. metal
plate), the system underpressure at the vacuum manometer must (see
point 4, pos. 7) must show a negative pressure, which is maximum 10%
below the maximum achivable negative pressure of the used vacuum
generator. Example: Vacuum generator reaches maximal -0,5bar. At the
manometer a negative pressure between -0,45 and -0,5bar must be
indicated.
X
X
Vacuum examination
During operating vacuum generation and without workpiece sucked to
the gripper the system underpressure at the vacuum manometer must
show a negative pressure between -0,2 and -0,4bar.
X
X
Visual inspection of check valves and flow resistors regarding dirt
X
X
Have the dust filter and silencer insert been cleaned?
X
X
Are the vacuum hoses in good condition (not brittle, not kinked, no signs
of abrasion) and thus free of leaks?
X
X
Is the rating plate still on the unit?
X
Is the Operating Manual available and are the users familiar with it?
X
Clean the sealing plate with a soft brush and a vacuum cleaner to remove
dirt such as wood chips and dust deposits
X
Check all connections and screws and tighten them as necessary
X
Check all hoses and connections for leaks
X
Remark:
Suspension, vacuum generator, vacuum hoses, dust filter are no part of the equipment FXC-HD.