11
System Settings
11.11 ECG
Page 132
Art
.
no.
:
2.
51
1335
Rev.
a
CARDIOVIT CS-104
11.11 ECG
Here the general ECG settings for acquisition and view are defined. Specific settings
for different recording types are defined following.
11.11.1
General
Lead Sequence
Standard or Cabrera
Rhythm lead 1, 2 and 3
Define the rhythm lead for display and print
Coding
Select the lead set used for the patient cable, IEC or AHA (
Identification and Colour Code, page 46)
Default Lead configuration
Select between the following:
– Standard 12 lead
– Paediatric
– Balanced
– Right precordials
– Standard with C4r
– Left posterior
– Nehb (chest)
11.11.2
Power Line
Set to local mains supply frequency - 50 Hz, 60 Hz, or off.
11.11.3
Display Filter
The Low pass filter suppresses disturbances caused by strong muscle tremor and
can be applied to stored ECGs and real-time ECGs. Depending on the recording
device, an ECG recorded in auto mode is stored unfiltered. It is therefore possible to
record, and print the stored ECG, either with or without a filter applied. In this screen
the filters available can be defined for resting ECG and exercise ECG. The filter
settings are Off, 25 HZ, 40 Hz and 150 Hz, and for exercise only, RNSF
1
. Any
combination of filters can be enabled and applied with the
Toggle Filter
icon
.
11.11.4
Analyser View
Here the settings for how the ECG is displyed when reviewed and includes Grid
colour, intensity, and trace thickness.
11.11.5
Print Output and PDF Output
Here the settings for how an ECG is printed or a PDF file is generated.and includes
grid colour, intensity, and trace thickness.
1. The RNSF filter is a dual purpose filter specifically used for exercise testing. It is designed
to help stabilise the baseline during exercise tests and to help reduce the physical and mus-
cle artefacts that can be present during exercise testing. The RNSF addresses artefact fre-
quencies both outside and within the ECG frequency range.
Содержание CARDIOVIT CS-104
Страница 1: ...User Guide CARDIOVIT CS 104 Art no 2 511335 Rev a 2 511335 ...
Страница 12: ...Page 12 Art no 2 511335 Rev a CARDIOVIT CS 104 ...
Страница 170: ...19 Annex Installation 19 5 Connection Overview Page 170 Art no 2 511335 Rev a CARDIOVIT CS 104 ...
Страница 172: ...Page 172 Art no 2 511335 Rev a 20 Index CARDIOVIT CS 104 ...