150
(1)Setting value of P3.92 < Setting value of P3.93
Motor current
position
OFF
ON
Position range 1
P3.92: Position range 1:Setting 1
P3.93: Position range 1:Setting 2
OFF
1000.00
3000.00
(2)Setting value of P3.92 > Setting value of P3.93
Motor current
position
ON
OFF
Position range 1
P3.93: Position range 1:Setting 2
P3.92: Position range 1:Setting 1
ON
1000.00
3000.00
Note:If setting 1 of range 1 of position (P3.92) is the same as setting 2 of range 1 of position (P3.93), range 1
of position is always turned off. The same is true for range 2 of position.
·Interrupt positioning detection: (Reference value 85)
This signal outputs the interrupt positioning motion mode status.
The signal turns on during interrupt positioning motion, and turns off with any of the following conditions:
①
When the interrupt input enabling signal is turned off after the positioning motion completion.
ON
OFF
Speed
FWD(REV)
Interrupt input
Interrupt positioning
detection
Interrupt input enable
P2.20
:
Interrupt
traveling unit amount
Time
ON
OFF
ON
In-position
OFF
OFF
ON
ON
OFF
OFF
ON
ON
The interrupt positioning detection will not turn off
even when the interrupt input enabling signal is
turned off during the interrupt positioning motion.
The interrupt positioning detection will turn off if the
interrupt input enabling signal is turned off after the
interrupt positioning completion ( in-position = ON)