Switches 2 and 3 are not used.
Settings in bold typeface in the table below show the factory default configurations.
1
Baud Rate
Configure the transmission rate of connected devices to the transmission rate of the camera.
Transmission Rate Switch 6 Switch 5
2400
OFF
OFF
4800
ON
OFF
9600
OFF
ON
19200
ON
ON
When protocol is set to “PELCO”, set to 2400.
2
Protocol
Select the protocol for controlling the camera.
Protocol
Switch 4
Corresponding Protocol
SSP (SANYO)
OFF
Automatic switching between Sanyo SSP and high speed SSP
PELCO
ON
Automatic switching between PELCO-D and PELCO-P
3
Terminator
If you connect multiple cameras, turn “ON” the terminator setting (switch 1) on the last device, and turn “OFF”
those on all other devices.
If you use the RS485 communication mode, assign a unique address (camera No.) to each camera.
Configure the address by setting the dip switches to “ON” and “OFF”.
Configure the switches according to the List of Address Configuration Switches shown below. Circles in the list
indicate “ON”.
Introduction 14/15