Construction
E - 21
Grounding
Grounding
Grounding
Grounding
(Maximum 8 units can be connected)
Bus system cable for group control
Remote
control
Remote
control
wiring
Indoor/outdoor
operation cable
Separately
sold item
Indoor
unit(UH)
Indoor
unit 2
Indoor
unit 3
Indoor
unit 8
Terminal board
for remote control
cabling
Terminal board
for remote control
cabling
Remote
control
cable
Remote
control
(parent)
Remote
control
(child)
Remote
control
(parent)
Remote
control
(child)
Separately
sold item
Separately
sold item
Separately
sold item
Separately
sold item
Bus system cable for
group control
Indoor/outdoor
operation cable
Grounding
Grounding
Grounding
Grounding
Indoor
unit(UH)
Indoor
unit 2
Indoor
unit 3
Indoor
unit
<Basic cable diagram>
Caution: Make sure there is no mistakes in the cabling. (Mistaken cabling will cause a breakdown.)
●
Cabling procedure
Carry out the cabling according to the following procedure.
1) Connect the remote control to the remote control terminal board (1, 2) of the group indoor unit 1.
2) Connect (1, 2) of the remote control terminal of group indoor unit 1 to (1, 2) of the remote control
terminal of group indoor unit 2, using a 2-wire bus system. Next, from indoor unit 2 connect to the
remote control terminal board of the next unit (indoor unit 3) in a bus system. In this way, connect all
the indoor units in a bus system.
3) Connect the indoor/outdoor operation cable.
4) The remote control cable has no polarity.
■
Control with 2 remote controls
❋
Control with 2 remote controls allows one or several indoor units to be operated with two remote controls.
(a maximum of 2 can be connected
* Two or more units of ‚c‚q‚V‚U type and ‚X‚U type cannot be connected to one refrigeration system
when there are other multi-type units connected.
❋
The set up method is the same as for “
1
Multi type for buildings”.
3. Points regarding electrical construction (indoor unit)
Содержание SGP-E120J2GU2
Страница 19: ...Outdoor Unit B 14 290 Type Performance characteristics of SGP E90J2GU2 5 Performance characteristics ...
Страница 20: ...Outdoor Unit B 15 3120 Type Performance characteristics of SGP E120J2GU2 5 Performance characteristics ...
Страница 21: ...Outdoor Unit B 16 4150 Type Performance characteristics of SGP E150J2GU2 5 Performance characteristics ...
Страница 22: ...Outdoor Unit B 17 5190 Type Performance characteristics of SGP E190J2GU2 5 Performance characteristics ...
Страница 49: ...Design D 5 2 Operating temperature ranges for heating and cooling Cooling Heating ...
Страница 87: ...Design D 43 8 Salt resistant specification ...
Страница 109: ...Construction E 22 4 Outdoor unit installation and construction ...
Страница 110: ...Construction E 23 4 Outdoor unit installation and construction ...
Страница 111: ...Construction E 24 4 Outdoor unit installation and construction ...
Страница 112: ...Construction E 25 4 Outdoor unit installation and construction ...
Страница 113: ...Construction E 26 4 Outdoor unit installation and construction ...
Страница 114: ...Construction E 27 4 Outdoor unit installation and construction ...
Страница 115: ...Construction E 28 4 Outdoor unit installation and construction ...
Страница 116: ...Construction E 29 4 Outdoor unit installation and construction ...
Страница 117: ...Construction E 30 4 Outdoor unit installation and construction ...
Страница 118: ...Construction E 31 4 Outdoor unit installation and construction ...
Страница 119: ...Construction E 32 4 Outdoor unit installation and construction ...
Страница 120: ...Construction E 33 4 Outdoor unit installation and construction ...
Страница 121: ...Construction E 34 4 Outdoor unit installation and construction ...
Страница 122: ...Construction E 35 4 Outdoor unit installation and construction ...
Страница 123: ...Construction E 36 4 Outdoor unit installation and construction ...
Страница 124: ...Construction E 37 4 Outdoor unit installation and construction ...
Страница 127: ...Construction E 40 5 Commissioning ...
Страница 128: ...Construction E 41 5 Commissioning ...
Страница 129: ...Construction E 42 5 Commissioning ...
Страница 130: ...Construction E 43 5 Commissioning ...
Страница 131: ...Construction E 44 5 Commissioning ...
Страница 132: ...Construction E 45 5 Commissioning ...
Страница 133: ...Construction E 46 5 Commissioning ...
Страница 134: ...Construction E 47 5 Commissioning ...
Страница 135: ...Construction E 48 5 Commissioning ...
Страница 136: ...Construction E 49 5 Commissioning ...
Страница 137: ...Construction E 50 5 Commissioning ...
Страница 138: ...Construction E 51 5 Commissioning ...
Страница 139: ...Construction E 52 5 Commissioning ...
Страница 140: ...Construction E 53 5 Commissioning ...
Страница 141: ...Construction E 54 5 Commissioning ...
Страница 142: ...Construction E 55 5 Commissioning ...
Страница 143: ...Separately Contents 1 Parts for the outdoor unit 1 Exhaust extension kit F 2 F 1 ...
Страница 150: ...Periodicinspection G 3 1 Periodic maintenance contract 70 90 Type 120 150 190 Type ...
Страница 154: ...Water heat exchange unit H 4 2 System characteristics Water heat exchanger unit connection limitations ...
Страница 155: ...Water heat exchange unit H 5 3 External view ...
Страница 158: ...Water heat exchange unit H 8 4 Specification 2 External dimension diagram ...
Страница 160: ...Water heat exchange unit H 10 4 Specification 4 Power characteristics 1Performance characteristics graph ...
Страница 161: ...Water heat exchange unit H 11 4 Specification ...