97
10
Application function 3 parameters
Control Method
Setting Range
V/f
Wit-
hout
PG
PG
V/f
PG
Para-
meter
Parameter
Functions
Fact-
ory
Defa-
ult
Torque
control
×
○ ○
○
○
○
○
○
○
○
×
×
×
74(1074):Count the run time of (commercial
power-driven motor) 3[mCRUN-M3]
75(1075):Count the run time of (commercial
power-driven motor) 4 [mCRUN-M4]
76(1076):Droop control [mDROOP]
77(1077):Cancel PG alarm [mPG-CCL]
81(1081):Clear all customizable logic
timers[mCLTC]
98:Run forward [mFWD]
99:Run reverse [mREV]
100:No function assigned [mNONE]
※
Setting the value in parentheses( )shown
above assigns a negative logic output to a
terminal.(True if OFF)
1: Step 1
2: Step 2
3: Step 3
4: Step 4
5: Step 5
6: Step 6
7: Step 7
8: Step 8
9: Step 9
10: Step 10
○
○
×
×
×
○
○
×
○ ○ ○
○
×
×
×
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
10
.
91
1
Customizable Logic:
monitor Timer
(step selection)
11
Serial communication function Parameter
Control Method
Setting Range
V/f
Wit-
hout
PG
PG
V/f
PG
Para-
meter
Parameter
Functions
Fact-
ory
Defa-
ult
Torque
control
×
○ ○
○
○
○
○
○
○
○
1~255
0: Immediately trip with alarm Er8
1: Trip with alarm Er8after running for the
period specified by timer
2: Retry during the period specified by timer.
If the retry fails, trip with alarm Er8
3: Continue to run
11
.
01
1
○
○
○
○
○
0
RS-485 communicat-
ion 1 communication
Station address
11
.
02
RS-485 communicat-
ion 1: Communicati-
ons error processing
0.0~60.0s
○
○
○
○
○
2.0
11
.
03 RS-485 communicat-
ion 1: timer
0:8 Bit 1:7 Bit
○
○
○
○
○
0
○
○
○
○
○
0
11
.
05
RS-485communicat-
ion1:data length
selection
0: No ( Stop bit : 2 )
1: Even parity ( Stop bit : 1 )
2: Odd parity ( Stop bit : 1 )
3: No ( Stop bit : 1 )
11
.
06
RS-485 communicat-
ion 1: parity check
selection
0: 2400bps
1: 4800bps
2: 9600bps
3: 19200bps
4: 38400bps
○
○
○
○
○
2
11
.
04 S-485 communicat-
ion 1: baud rate