Keypad
Display
Item
Unit
Description
PID Feedback
amount
Stop position target
pulse (synchronous
operation)
Current Position
Pulse (synchronous
operation)
Position deviation
pulse (synchronous
operation)
Control Status
Pulse (synchrono-
us operation)
PID Output Value
Running Status 2
Motor Temperature
Magnetic flux
command value
Current position
pulse, 4-multiplied
Position deviation
pulse, 4-multiplied
Ratio setting
Line Speed
Reserved
None
None
None
Pulse
Pulse
Pulse
Pulse
Pulse
The PID feedback amount is displayed after conversion to the
virtual physical values (e.g., temperature or pressure) of the
object to be controlled using function parameter 01
.
40 and 01
.
41 data (PID display coefficients A and B).
Display value = (PID feedback amount) ×(Coefficient A - B) + B
When PID control is set as no action, it displays “----”.
When this setting is 100%, the LED monitor shows 1.00 time
of the value to be displayed.
When no rate setting value is selected, it displays “----”.
Display Value=(Output Frequency Hz) × Functional Param-
eter 01.50 (speed display coefficient)
When display value is more than 10000, ×10 LED is on and
line speed= display value × 10.
Display current control status
0: No action for synchronous control
20: synchronous control canceled
21: synchronous control stopped
22: Z=phase detection waiting
23: Reference Z-phase detection
24: Following Z-phase detection
25: In synchronous control
26: synchronous control completed
Current position pulse for positioning control
Stop position target pulse for positioning control
Position deviation pulse for positioning control
Display PID output value, displayed in % (assuming the maxi-
mum frequency as 100%).
When PID control is set as no action, it displays “----”.
Display the run status 2 in 4-bit in hexadecimal. Refer to ■
Run Status (C_07 ) and Display Method of Run Status 2
(C_23 ) on the following page on detailed information.
Temperature detected by the NTC thermistor built in the motor.
When it is not connected NTC thermistor setting, it displays
It displays Flux command value in %.
Current position pulse for positioning control (server locking)
Current position pulse for positioning control (server locking)
Driving torque limit value A (based on motor rated torque)
Braking torque limit value B (based on motor rated torque)
Torque Limit Value
Torque Limit Value
Reserved
Reserved
36
Содержание S3800C Series
Страница 17: ...S3800C S3800C S3800C S3800C S3800C S3800C 14 ...
Страница 18: ...FALSE frequency carrier carrier frequency 00 26 15 ...