51
①
Check if operation/set switch is [set] mode.
②
Press choice switch to set “ on indicator.
③
Sensitivity control by ▲ switch (increase sensitivity, indicator number is increased) or
▼switch (decrease sensitivity, indicator number is decreased). This is the best suited
set on delivery, then other control doesn't need but in case of necessary, the
following order is controlled. (Sensitivity control is feasible 1 to 5)
A. Clutch lever is coming and going to decrease sensitivity.
B. The more clutch controller of remote controller move a lot the more clutch lever
move. If it is less move and clutch lever is no movement, set sensitivity high.
④
Above [3] item control is over, press Input switch.
⑤
In case of not the initial set, set operation/set switch to [operation]. Indicator would
be displayed 0 at normal operation.
Standard value set (initialize set value on delivery)
①
Check if operation/set switch is [set] mode.
②
Press choice switch to set “ on indicator.
③
Press Input switch.
④
In case of not the initial set, set operation/set switch to [operation], then indicator
would be displayed 0 at normal operation.
3.3 Functional setup (Setup + Power ON)
With ship's engine is off, check all electric wire, portable transmitters wire and fushble
cable locking condition, set operation/set switch [set] position.
With pressed choice switch, switch on power supply switch(install outside of unit) and
supply power.
Release a hand on pressed choice switch.
Governor auto scope set.
Auto scope means governor position is set high and engine is high revolving. If turn clutch
controller, governor would be slow and clutch lever is auto-operated at the same level of
controller which means to protect engine and clutch.
①
Press choice switch to set 1 on indicator.
②
Press ▲ switch or ▼ switch to control governor lever of Control lever(manual
controller) to be position where could control clutch (engine revolving speed)
③
Press Input switch
Caution Notice all item which is set by user is deleted and initializes as set value on
delivery.
Caution As all control is completed, make sure that return to [operation] position.
52
④
In case of not the initial set, set operation/set switch to [operation]. After power off,
switch on after 5 seconds. It would be back to normal operation.
3.4 Default values for operation / functions
Standard value on delivery is as follows,
<
Operation Set Initial value>
1 Governor full speed position - pull cable to position lever 45°
2 Governor low speed position - push cable to position lever 45°
3 Clutch ahead position - pull cable to position lever 45°
4 Clutch ahead neutral position - pull on the center of cable to position 45°
5 Clutch astern position - push cable to position 45°
“ Clutch astern neutral position - push on the center of cable to position 45°
” Governor sensitivity – 3
8 Clutch sensitivity - 3
<Function Set Initial Value>
1 Governor Auto Scope - 10 %
Caution As setting with engine start-off, test auto scope by manual lever before set,
control balance with revolving speed of engine.