English
_21
●
in
St
aLL
ation & connection
installation & connection
`
camera wiring interface Board
For the camera wiring, please refer to the picture below.
J
`
Select Normal Open in the setup menu.
-
The sensor input is activated during a short for contact type, or when it is at “Low” level for
the active type.
`
Select Normal Close from the Setup menu.
-
The sensor input is activated when open for the contact type or when in high impedance
state (open collector) for the active type.
`
The maximum capacity of the alarm output terminal is 30V DC/2A, 125V AC/0.5A and 250V
AC/0.25A.
`
When connecting alarm input and output cables, be sure to connect one cable to each
terminal respectively.
`
To connect products over the camera’s capacity, please use an additional relay device.
`
If power and GND cables are connected inappropriately to the NC/NO or COM port, a fire or
breakdown of equipment may occur.
AUDIO OUT
AUDIO IN
D+
D-
TXD+ TXD-
GND
GND
1.COM
1.NO
1.NC
IN1
IN2
GND
IN3
IN4
2.COM
2.NO
2.NC
AC-
FG
AC-
D+
D- TXD+ TXD- GND
Communications
Refer to Control Signal
Connection Diagram
ETHERNET
Audio
IN
Audio
OUT
(SNP-L5233 : AC 24V, 2.5A/
SNP-L5233H : AC 24V, 3A)
Power Input
Ground
Power
Supply
Alarm
Alarm Input
Alarm output
Video
Output