appendix
142_
appendix
communication protocol Dip Switch Settings (Sw1)
SW1 Pin No.
Purpose
1
Set transmission protocol (RS-485/422)
2
Termination setting 1
3
Termination setting 2
4
Reserved
•
Communication Method settings
Select a communication method for the camera.
Function
ON
OFF
SW1-#1
Transfer Mode Switch
RS-422(4Wire)
RS-485(2Wire)
•
Termination settings
To prevent the attenuation of communication signals between the camera and controller,
the items at the end of line must be set up with the termination settings.
Camera Input Position
SW1-#2
SW1-#3
Termination of Longest Path
ON
ON
On the Path
OFF
OFF
M
`
The default value is shaded in each setting table.
`
To use a third party controller with this product, please contact our After-Sales Service or
Technology Department.
ON
OFF
SW1
ON