3-18
3. Disassembly and Reassembly
Part
Photo
Description
Distributor Motor
(DMT800 /
DMT700 )
The distributor motor is located under the tub at the middle, rear the circulation motor. The
distributor motor operates to select
fl
ow direction at the dishwasher sump when select half load
or storm wash option.
Preparation:
*
Disassemble the cover sump & case scroll.
-
Refer the “cover sump” disassembly section.
*
Disassemble the shutter.
-
Refer the “shutter” disassembly section.
1.
Remove the distributor motor connector.
2.
Remove the two (2) screws that hold the
distributor motor in place.
3.
Pull out the distributor motor and micro switch
holding by hooks.
Be careful removing it because it has cam-switch
and a seal in opposite side.
Circulation
Motor
Preparation:
*
Disassemble the cover sump & cutter disposer and
shutter.
-
Refer the each disassembly section.
1.
Remove the circulation motor and capacitor
connection.
2.
Remove the four(4) screws holding the circulation
motor and the sump in place,and the one(1) screw
for earth connection from main wire-harness.
3.
Hold and pull out the circulation motor carefully to
remove it from the sump.
Caution
Make sure to remove remain water in the
dishwasher. If not, wet the
fl
oor.
Caution
Be careful don’t break oil seal when removing them.
坍
Reassembly is in the reverse order of the removal.