3-7
3. Disassembly and Reassembly
Part
Photo
Description
Condensing dry
system
Air Diffusion Condensing Dry system
This system circulates and combines air from inside the
dishwasher with outside air to dry the dishes quickly
and ef
fi
ciently. This process is designed to use as little
energy possible while exhausting the least amount of
hot and humid air back into the room.
h GkGjG
h GjG}
h k Gk
Preparation:
* Disassemble the frame front & Assy control panel.
- Refer the “Frame front” disassembly section.
1. Remove the two(2) connectors from thermal actuator
& Dry Fan motor.
2. Open the door & Remove the three(3) screws
holding the bracket cover fan and Assy case vent.
3. Remove the cover fan by rotating using a tool.
(counterclockwise)
NOTE : Use a jig. If you have no jig, use a tool
such as a long nose pliers. Remove it carefully so that
the part is not damaged.
4. Remove the four (4) screws to release the bracket
door link and remove Assy dry system.
Be careful while removing them as the duct
condenser is touching the bracket door link and the
cushion duct.
坍
Reassembly is in the reverse order of the removal.
Содержание DMT400 series
Страница 10: ...2 5 2 Features and Specifications Memo ...