4. Troubleshooting
4-8
Error type
Error mode
Checking Method
Corrective actions
High temperature Water
supply error
3E
[Or]
‘Normal’ +
‘Delicate’ +
‘Smart Auto’
LED
1. Check the hot water connections for the Inlet Valve.
- Adjust the hot water supply so that the temperate of the supplied water is
less than 176
˚
F (80
˚
C)
2. Check the operation of the Thermistor.
- See the “Temperature sensor error”..
Drain error
5E
[Or]
‘Delicate’ LED
1. Check whether there is any foreign material in the
Drain Hose.
- Remove the foreign material from the Drain Hose.
2. Check the operation of the Water-level sensor
- See the “Low-level water error”
3. Check the connections for the Drain Pump
connector.
- Reconnect the Drain Pump connector.
4. Check whether the Drain Pump coil is conductive.
(Remove the connector before measuring.)
Normal: Approx. 25
Ω
¯
- Faulty: Replace the Drain Pump.
5. Check the operation of the Drain Pump Relay
: Check the operating voltage between the yellow
wire of the Main PBA CN101 connector and the
orange wire of the CN202 connector.
Normal: 120V (while operating)
¯
- Faulty: Replace the Main PBA assy.
- Normal: Replace the Drain Pump.
- Remove retainer.
- Check voltage.