4. Troubleshooting
4-17
Error type
Error mode
Checking Method
Corrective actions
Dry is not satis
fi
ed.
None
1. Check whether Rinse Re
fi
ll LED light or not.
- If Rinse Re
fi
ll LED light, re
fi
ll rinse in Dispenser.
2. Check the wire connections for the Dry Fan Motor.
- Reconnect the Dry Fan Motor connectors.
3. Check the resistance of the Dry Fan Motor coil.
(Remove the connector before measuring.)
Normal: Approx. 80
Ω
¯
- Faulty: Replace the Dry Fan Motor assy.
4. Check the resistance of the Thermal Actuator.
(Remove the connector before measuring.)
Normal: Approx. 73
Ω
¯
- Faulty: Replace the Main PBA assy.
- Check
voltage
5. Check the operation of the Dry Fan Motor Relay
: Check the operating voltage between the yellow wire of the
C101 connector and the sky wire of the CN201 connector.
Normal: 120V (while operating)
¯
- Faulty: Replace the Main PBA assy.
- Remove
retainer.
- Check
voltage.
6. Check the operation of the dispenser.
If rinse aids are not dispensed, a dry error may occur.
¯
Because the dishes are heated and heat dried during the last
drying cycle, the dried state of plastic dishes may not be
optimal
- See “Detergent is not dispensed”