4. Troubleshooting
4-15
Error type
Error mode
Checking Method
Corrective actions
The Cycle does not
start.
None
1. Check the connections for the Door Sensing Switch
: Check the blue wire and the switch connected to the
blue wire.
Normal (Power Key On): 9.5 to 12.5V (when the
¯
door is open)
Normal (Power Key Off): 5.5 to 7.0V (when the
¯
door is open)
Normal : <2V (when the door is closed)
¯
- Reconnect the Door Sensing Switch connectors
2. Check the operation of the Door Sensing Switch.
(Remove the connector before measuring.)
: Check the blue wire and the switch connected to the
blue wire.
Normal: OPEN (when the door is open)
¯
Normal: SHORT (when the door is closed)
¯
- Faulty: Replace the Door Sensing Switch.
- Normal: Replace the Main PBA assy.
No Washing
None
1. Check whether the nozzle injects water normally.
- See “The nozzle does not inject water”.
2. Check the operation of the Heater.
- See “Heater Error”.