4. Troubleshooting
► Error Code
A1–1611
A1–1612
A1–1613
► Error message
Motor Failure: #A1-1611. Turn off then on. Call for service if the problem persists.
Motor Failure: #A1-1612. Turn off then on. Call for service if the problem persists.
Motor Failure: #A1-1613. Turn off then on. Call for service if the problem persists.
► Symptom
ITB motor operation is abnormal
► Troubleshooting method
•
A1–1611 : ITB motor is stopped but machine recognizes it as operational.
•
A1–1612 : ITB motor is not operated for print-job.
•
A1–1613 : ITB motor is operating but machine recognizes status as "Stopped".
1) Turn the machine off then on. If the error persists, turn the machine off again.
2) Open the side cover. Remove the ITB unit
(
Refer to 3.2.2.4 ITB Unit in chapter 3
)
3) Remove the rear cover after removing 10 screws.
4) Check if the ITB motor connector is connected correctly.
5) If the connection is OK, turn the machine on. Enter SVC mode. Select motor test.
4-67